34
Once installed, install the chain linking the servomotor with the air inlet damper as shown above. The chain must have
a set of 1/8". When there is no call for heat, the air inlet damper must be completely closed and the chain must be
hooked to the servomotor at the “8 o’clock” position.
Then, you must connect the servomotor and the link
board. Take the wires out of the servomotor and enter
the wires in the wire cover through the grommet. Pull
them out through the grommet next to the link board
housing.
For connection, refer to wiring diagram.
WARNING: USE WIRING SUITABLE FOR 75 °C
(not included).
14.6. UNIT LOCATION
For a safe and quiet operation, the furnace must be leveled in both directions and supported evenly to ensure stability.
The furnace must be installed where outside air supply will be sufficient for proper combustion. In airtight houses, it
might be necessary to install an outside air inlet (See Section 14.11 - COMBUSTION AIR AND FRESH AIR INTAKE
ADAPTER INSTALLATION (OPTIONAL))
The furnace must be positioned so that the connector is as short as possible. Minimize the use of 90
o
elbows.
The owner must ensure a proper installation to allow a safe operation of the appliance
.
14.7. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS AND FLOOR PROTECTION
N.B.: This appliance must be installed in accordance with the instructions on the certification plate
applied on the unit.
Summary of Contents for PF01015
Page 10: ...10 ADD ON WOOD ONLY WOOD ELECTRIC WOOD OIL ...
Page 13: ...13 INSTALLATION AND OPERATION INSTRUCTIONS CADDY ADD ON SERIAL INSTALLATION PF01015 ...
Page 16: ...16 Option 3 Option 4 ...
Page 17: ...17 EXAMPLE 1 EXAMPLE 2 ...
Page 63: ...63 20 GENERAL ELECTRICAL DIAGRAM STANDALONE FURNACE ...
Page 64: ...64 21 ELECTRICAL DIAGRAM FOR PARALLEL FURNACE ...
Page 65: ...65 22 ELECTRICAL DIAGRAM FOR ELECTRIC UNIT ...
Page 78: ...78 31 ELECTRICAL DIAGRAM BECKETT OIL UNIT ...
Page 79: ...79 32 ELECTRICAL DIAGRAM RIELLO OIL UNIT ...
Page 81: ...81 33 4 AIR CONDITIONNING DAMPER 33 5 HUMIDIFIER 33 6 HEAT PUMP ...
Page 82: ...82 34 EXPLODED VIEW AND PART LIST ...
Page 83: ...83 ...
Page 84: ...84 ...
Page 85: ...85 ...
Page 86: ...86 ...
Page 87: ...87 ...
Page 88: ...88 ...
Page 89: ...89 ...