Synchronizing local time with an external source
Perform the following steps to synchronize the local time of the principal or primary FCS device with that of an external NTP server.
1. Log into the device using one of the following methods:
•
A serial console connection to the active CP blade. The active CP is indicated by an illuminated blue LED on the blade front
panel.
•
A Telnet session using the chassis management IP address.
2. Log into the device using
admin
. If you have not changed the default password, use
password
.
3. Enter the
tsClockServer
ipaddr
command.
The
ipaddr
variable represents the IP address of the NTP server that the device can access. This argument is optional; by
default, the value is "LOCL".
switch:admin> tsclockserver 192.168.126.60
Updating Clock Server configuration...done.
Updated with the NTP servers
Customizing the chassis and switch name
Refer to the considerations and rules for creating switch, fabric, and chassis names listed in the Fabric OS Administration Guide.
NOTE
Changing the name causes a domain address format RSCN to be issued.
1. Log into the device using one of the following methods:
•
A serial console connection to the active CP blade. The active CP is indicated by an illuminated blue LED on the blade front
panel.
•
A Telnet session using the chassis management IP address.
2. Log into the device using
admin
as your password. If you have not changed the default password, use
password
.
3. Enter
chassisName
followed by the new name.
switch:admin> chassisname Chassis_01
A message displays explaining that the chassis name change is applied and the new name will display at next login. You can
enter
chassisName
to verify the new name after login.
4. To change the switch name, enter
switchName
followed by the new name.
swDir:admin> switchName Switch_01
Committing configuration...
Done.
Switch name has been changed.Please re-login into the switch for the
change to be applied.
A message displays that the name change is applied and the new name will display at next login. You can enter
switchName
to
verify the new name after login.
5. Record the new names for future references.
Customizing the chassis and switch name
Brocade X6-4 Director Hardware Installation Guide
80
53-1004106-07
Summary of Contents for X6-4
Page 12: ...Brocade X6 4 Director Hardware Installation Guide 12 53 1004106 07...
Page 20: ...Brocade X6 4 Director Hardware Installation Guide 20 53 1004106 07...
Page 28: ...Brocade X6 4 Director Hardware Installation Guide 28 53 1004106 07...
Page 64: ...Brocade X6 4 Director Hardware Installation Guide 64 53 1004106 07...
Page 86: ...Brocade X6 4 Director Hardware Installation Guide 86 53 1004106 07...
Page 102: ...Brocade X6 4 Director Hardware Installation Guide 102 53 1004106 07...
Page 130: ...Brocade X6 4 Director Hardware Installation Guide 130 53 1004106 07...
Page 140: ...Brocade X6 4 Director Hardware Installation Guide 140 53 1004106 07...
Page 166: ...Brocade X6 4 Director Hardware Installation Guide 166 53 1004106 07...
Page 196: ...Brocade X6 4 Director Hardware Installation Guide 196 53 1004106 07...
Page 200: ...Brocade X6 4 Director Hardware Installation Guide 200 53 1004106 07...
Page 204: ...Brocade X6 4 Director Hardware Installation Guide 204 53 1004106 07...
Page 210: ...Brocade X6 4 Director Hardware Installation Guide 210 53 1004106 07...
Page 224: ...Brocade X6 4 Director Hardware Installation Guide 224 53 1004106 07...
Page 238: ...Brocade X6 4 Director Hardware Installation Guide 238 53 1004106 07...