Model name
@240 VDC
input
@ 100 VAC
input
@380 VDC input
@ 240 or 277 VAC
input
Minimum number of power supplies
Notes
One power supply provides system power, but two must be
installed to provide power efficiency and redundancy.
4 FC32-48 port blades,
2 fan assemblies
Brocade X6-8
2561 W
8741 BTU/hr
2506 W
8553 BTU/hr
2 power supplies for DC input (192–400 VDC)
3 power supplies for AC low line (100–120 VAC)
2 power supplies for AC high line (200–277 VAC)
Two power supplies provide system power, but 4 must be
installed to provide power efficiency and redundancy.
Brocade X6-8 fully
loaded: 2 CP blades,
2 CR blades,
8 FC32-48 port blades,
3 fan assemblies
Power consumption for HVAC/HVDC power supplies
(idle configuration)
No optics or connections, ports disabled, and system completed boot up, fans at low speed.
Model name
@240 VDC
input
@ 100 VAC
input
@380 VDC input
@ 240 or 277 VAC
input
Minimum number of power supplies
Notes
Brocade X6-4
813 W
2775 BTU/hr
796 W
2717 BTU/hr
1 power supply for DC input (192–400 VDC)
2 power supplies for AC low line (100–120 VAC)
1 power supply for AC high line (200–277 VAC)
One power supply provides system power, but two must be
installed to provide power efficiency and redundancy.
Brocade X6-4 fully
loaded: 2 CP blades,
2 CR blades,
4 FC32-48 port blades,
2 fan assemblies
Brocade X6-8
1465 W
5000 BTU/hr
1434 W
4894 BTU/hr
2 power supplies for DC input (192–400 VDC)
3 power supplies for AC low line (100–120 VAC)
2 power supplies for AC high line (200–277 VAC)
Two power supplies provide system power, but 4 must be
installed to provide power efficiency and redundancy.
Brocade X6-8 fully
loaded: 2 CP blades,
2 CR blades,
8 FC32-48 port blades,
3 fan assemblies
Power consumption for HVAC/HVDC power supplies
(maximum configuration)
The maximum power consumption configuration features fans at maximum speed and the FC32-48 blade installed with optics. Traffic is
at full-line rate, smallest packet is 64-bytes, 40°C (104°F) ambient temperature, and maximum power for all supported optics. Does not
include the power draw for the SX6 extension blade.
Power consumption for HVAC/HVDC power supplies (maximum configuration)
Brocade X6-4 Director Hardware Installation Guide
53-1004106-07
233
Summary of Contents for X6-4
Page 12: ...Brocade X6 4 Director Hardware Installation Guide 12 53 1004106 07...
Page 20: ...Brocade X6 4 Director Hardware Installation Guide 20 53 1004106 07...
Page 28: ...Brocade X6 4 Director Hardware Installation Guide 28 53 1004106 07...
Page 64: ...Brocade X6 4 Director Hardware Installation Guide 64 53 1004106 07...
Page 86: ...Brocade X6 4 Director Hardware Installation Guide 86 53 1004106 07...
Page 102: ...Brocade X6 4 Director Hardware Installation Guide 102 53 1004106 07...
Page 130: ...Brocade X6 4 Director Hardware Installation Guide 130 53 1004106 07...
Page 140: ...Brocade X6 4 Director Hardware Installation Guide 140 53 1004106 07...
Page 166: ...Brocade X6 4 Director Hardware Installation Guide 166 53 1004106 07...
Page 196: ...Brocade X6 4 Director Hardware Installation Guide 196 53 1004106 07...
Page 200: ...Brocade X6 4 Director Hardware Installation Guide 200 53 1004106 07...
Page 204: ...Brocade X6 4 Director Hardware Installation Guide 204 53 1004106 07...
Page 210: ...Brocade X6 4 Director Hardware Installation Guide 210 53 1004106 07...
Page 224: ...Brocade X6 4 Director Hardware Installation Guide 224 53 1004106 07...
Page 238: ...Brocade X6 4 Director Hardware Installation Guide 238 53 1004106 07...