LINKUP 5294 WITH DL5294 FIRMWARE
228
Setup Screen
Field
Setting/Comments
COMM
Transmit = (baud rate)
Set to match converter
Receive = (baud rate)
Transmit
XOFF
128
Bits, Parity (main port)
Set to match converter
Stop Bits
Set to match converter
Local Echo
No Local Echo
Port Type
EIA Port, Data Leads only
Disconnect Delay
Two-second Delay
PRINTER
Speed = (baud)
As required by printer
Mode
Normal Print
Bits, Parity (aux port)
As required by printer
Stop Bits
As required by printer
Print Full Page/Scroll Reg.
Scroll region
Printed Data Type
Determined by type of printer attached
Print Terminator
No Terminator
KEYBOARD
Key Types
As determined by your application and
country
Caps/Shift Lock
As desired
Auto Repeat
As desired
Keyclick
As desired
Margin Bell
As desired
Warning Bell
As desired
Break/No break
No Break
Auto Answerback
Off
NOTE
The PR port on the VT220 is used for the Auxiliary Printer feature. For a description of
this feature, see the appropriate user’s guide. This port requires a male DB9 connector
on the interface cable.
F.32 WY30 Terminal Module - Wyse WY30
The following list identifies the key sequences defined for the WY30 Terminal Module.
1. Press the <CTRL> key concurrently with the indicated alpha key.
2. Press the <ESC> key prior to pressing the indicated alpha key.
5250 Function
Key Sequence
Hex Value Generated
Cursor Movement
Character Backspace
left arrow
03H
Cursor Up
up arrow
0BH
Cursor Down
down arrow
0AH
Cursor Left
left arrow
08H
Cursor Right
right arrow
0CH
Field Advance
right arrow|
09H
Field Backspace
left arrow|
01H 40H 0DH
New Line
NEW LINE symbol
0EH
Fast Left
N.A.
N.A.
Fast Right
N.A.
N.A.