APPENDIX F: Terminal Modules and ASCII Terminal Setups
187
Keyboard/Printer Menu
Parameter
Set to:
Comments
Enter
As desired
When set to RETURN (*) will cause numeric keypad
ENTER to work as Field+ key. When set to SEND,
numeric keypad key will work as Enter/Record
Advance has to be done every time after entering
emulation key.
Return
NEW LINE (*)
New Line
CR
Return/Enter keys generate CR character (*)
Send
PAGE
Selects code for Send key
Insert Character
SPACE (*)
MODE setting disabled INSERT key
Printer options should be set as appropriate for an auxiliary printer.
1. The port on the rear of the IBM 3151 farthest from the powa cord is the standard EIA interface
(main port).
2. The other port on the rear of the IBM 3151 is used for the Auxiliary Printer feature. For a description
of this feature, see the appropriate User’s Guide.
3. The pacing function (flow contol) on the IBM 3151 main port is performed only when the
communication parameter, Line Control, is set to either PRTS or IPRTS. The flow control options on
the LinkUp 5294 should be set to XON.
F.18 I3161 Terminal Module - IBM 3161/3163
The following list identifies the key sequences defined for the I3161 Terminal Module.
1. Press <CTRL> concurrently with the indicated alpha key.
2. Press <ESC> prior to pressing the indicated alpha key.
5250 Function
Key Sequence
Hex Value Generated
Cursor Movement:
Character Backspace
BACKSPACE
08H
Cursor Up
up arrow
1BH 41H
Cursor Down
down arrow
1BH 42H
Cursor Left
left arrow
1BH 44H
Cursor Right
right arrow
1BH 43H
Field Advance
TAB
09H
Field Backspace
BACKTAB
1BH 32H
New Line
LINE FEED
0AH
Fast Left
N.A.
N.A.
Fast Right
N.A.
N.A.
Special Control:
Error Reset
CTRL/R
12H
or F12
1BH 6CH 0DH
or SHIFT/F12
1BH 21H 6CH 0DH
Insert Mode
INS LN
1BH 4EH
or F3
1BH 63H 0DH