CHAPTER 7: Operation
51
•
Character Display Test (Option 21) —
This option generates a continuous output of the alphabet test
message on your async port. The character display test is shown below. This option is also available in
Port Test Mode.
•
Character Echo Test (Option 22) —
The Character Echo Test causes the LinkUp 5294 to echo each
key typed from the keyboard. This includes Attention Keys and Escape (ESC) sequences. Care should
be taken in using this test. Typing other than the displayable ASCII character set (Hex 20 through
Hex 7E) may cause unpredictable results. This option is also available in Port Test Mode. Type
<Enter> twice to return to the options menu.
+/0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ{\}^`abcdefghijk
lmnopqrs/0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWX
YZ{\}^`abcdefghijklmnopqrs/0123456789:;<=>?@ABCDEFGHIJKLM
NOPQRSTUVWXYZ{\}^`abcdefghijklmnopqrs/0123456789:;<=>?@A
BCDEFGHIJKLMNOPQRSTUVWXYZ{\}^`abcdefghijklmnopqrs/0123
456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ{\}^`abcdefghijklmnop
qrs/0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ{\}^`
abcdefghijklmnopqrs/0123456789:;<=>?@ABCDEFGHIJKLMNOPQ
RSTUVWXYZ{\}^`abcdefghijklmnopqrs/0123456789:;<=>?@ABCDE
FGHIJKLMNOPQRSTUVWXYZ{\}^`abcdefghijklmnopqrs/012345678
9:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ{\}^`abcdefghijklmnopqrstuv
wxyz+/0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ{\}^`abcde
fghijklmnopqrs/0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTU
VWXYZ{\}^`abcdefghijklmnopqrs/0123456789:;<=>?@ABCDEFGHIJ
KLMNOPQRSTUVWXYZ{\}^`abcdefghijklmnopqrs/0123456789:;<=>
?@ABCDEFGHIJKLMNOPQRSTUVWXYZ{\}^`abcdefghijklmnopqrs/
0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ{\}^`abcdefghijkl
mnopqrstuvwxyz
•
LU and Async Port Summary (Option 23) —
This function displays certain configuration parameters
for each Logical Unit, along with information about the state of the LU and the keyboard. Async port
configuration parameters are also displayed. This display requires two pages for the LU Summary,
and up to four pages for the Async Port Summary.
Two Consecutive CRs - Options Menu
Two Keys are active during this test:
Press <N> (for next) to display the next page of data.
Press <Enter> to return to the options menu.
The LU Summary screen is shown below. The Async Port Summary is shown on top of the next page.
****] C193-27E8 [C173-] C100 - 2D0000000001 - 6B8001...[
CR - Options Menu; SPACE Freeze/Start Display; * - Reset Trace
Loss of data
continuity
indicating
the beginning
of the trace.
Link
Header
Link
Header
SNA
information
unit
Transmission
Header
2 byte
CRC
LinkUp