LINKUP 5294 WITH DL5294 FIRMWARE
130
13.0 CNFIGSSP - REMOTE CONTROLLER DEFINITION
1. Remote Controller ID
C02
2.Describe the remote controller
LinkUp 5294 Remote Controller
3.Controller type
1
1. 5251 model 12
2. 5294
4.Controller station address
01-FD
02
5. Communications line
1-8
2
6.For a switched line, optionally specify
1 to 3 alternative lines
Cmd2-Scan Cmd3-Previous menu Cmd5-Add Controller
Cmd6-Restart Cmd9-Delete remote controller
STEP 8
Display 14.0 (CNFIGSSP - Remote Cluster Definition) is shown below. Use this display to add display
stations and printers to a new remote controller (the LinkUp 5294). Enter the number of devices
attached to each port of the LinkUp 5294. Configure the ports according to a dual -cluster feature. The
LinkUp 5294 can accommodate up to 8 different units (one to each cluster port or any combination of
display units and auxiliary printers per port up to 8 devices). For our example, one device is added for
Ports 1, 2, and 3.
NOTE
You must have one device on the previous port before using another port on the same
cluster. For example, you cannot specify a device on Port 3 if one is not specified on
Port 2.
14.0 CNFIGSSP-REMOTE CLUSTER DEFINITION
Specify up to four display stations or printers attached to
each cluster feature below:
SINGLE CLUSTER FEATURE
Port number
1 2 3 4
Number of display
stations and printers
1 1 1 0
DUAL CLUSTER FEATURE
Port number
5 6 7 8
Number of display
stations and printers
0 0 0 0
Cmd 19 - Cancel