CHAPTER 7: Operation
75
instructions carefully:
1. Turn off and unplug the LinkUp 5294.
2. Loosen the thumbscrews on either side of the main circuit board and slide the circuit board part way
out. Move the two-position switch located near the PROM cartridge from the RUN position to the
SETUP position. Carefully slide the main circuit board back into position, making sure that the
CHANNEL SELECT and RESET buttons do not bind on the front panel.
3. Plug the LinkUp 5294 in and turn it on.
4. Connect a suitable display terminal (or PC with appropriate terminal emulation software installed)
to Port 2 and power it on. The terminal must be set to operate with 8 bits and no parity. Its baud rate
may be set for 300, 1200, 2400, 4800, 9600 or 19200.
5. Press <Enter> twice on your terminal to display the Connect Mode sign-on menu.
6. Proceed as though you wished to enter Configurator Mode: specify your terminal type, then answer
<1> in response to the Enter LU number prompt.
7. Because of the setting of the internal RUN/SETUP switch, you will not enter Configurator Mode,
but will instead enter Setup Mode. As shown in Figure 7-2, you must now enter the Setup Mode
password; both DALYNX and SETUP are valid passwords, as shipped from the factory.
8. When the message appears telling you to reset the LinkUp 5294, all ports and LUs will have been set
to their factory default parameters in EEPROM. Return the RUN/SETUP switch to the RUN
position by taking the appropriate actions as described in Step 2.
9. Proceed to Configurator Mode to define the port and LU parameters as you desire.
Enter Device Type (HZ51): <Enter>
Enter LU Number (2): 1 <Enter>
****SETUP MODE****
ENTER SETUP PASSWORD DALYNX <Enter>
PARAMETER STORAGE IN PROGRESS.
SWITCH TO CONFIGURATOR MODE
AND RESET LINKUP 5294.
Figure 7-2. Sample Setup Mode Session.