LINKUP 5294 WITH DL5294 FIRMWARE
134
At Display 1.0 (CONFIGSSP - Main Menu), enter Option 12 (Apply change to the master configuration
record). See below.
1.0 CONFIGSSP - MAIN MENU
Select one of the following:
1.How to use CNFIGSSP
2.Create, change, or delete a configuration member
3.Review a configuration
4.Print a configuration
10.Configuration report aids
12.Apply change to the master configuration record
13.Rebuild the master configuration record (update to next release)
14. End CONFIGSSP
Option: 12
Cmd3-Previous menu
Help text is available throughout the CONFIGSSP Procedure
by pressing the help key
STEP 15
Display 3.0.
Prompt 1: Enter the configuration member added in Section A (SYSCNFIG).
Prompt 2: Enter the library name where the configuration member is stored (#CNFGLIB).
Press <Enter>.
3.0 CONFIGURATION MEMBER DEFINITION
Member name
SYSCNFIG
Library name
#CNFGLIB
STEP 16
WARNING
Be sure to select Option 3 for displays and printer. Any other option could crash the
system.
Display 7.0
Select Option 3. This option allows you to update only the display station and printer portion of the
master configuration record.
After all changes have been copied to the Master Configuration Record, you will be asked if you want a
printout of this configuration. Specify YES. After the configuration has been printed, press <Enter>. The
system will automatically perform an IPL, and the new line with remote devices will be recognized by the
System/36.