Safety Functions
Operation Manual
Safety Module for b maXX 5000
BM5-O-SAF-002/3
Document no.: 5.11016.03
63
10
10.5 Safe Stop 2 (SS2)
NOTE!
The safety function SS2 is supported by the Safety Modules SAF-002 and SAF-003.
After activating the safety function „Safe Stop 2 (SS2)“ the drive is braked to an operating
stop by the drive control. After the pre-parameterized delay time (SS2-time) the drive is
set to the state SOS (Safe Operating Stop). Thereby the braking ramp is not monitored.
m
The safety function complies with the stop category 2 as per EN 60204-1.
Figure 22:
Safety function SS2 without monitoring of the brake ramp
During noncompliance with the following function "SOS" after a parameterizable "SS1" time "
"STO" was initiated.
Summary of Contents for BM5-O-SAF-002