Technical data
Operation Manual
Safety Module for b maXX 5000
BM5-O-SAF-002/3
Document no.: 5.11016.03
171
C
C.5.3
BM5-O-SAF-00x-001-000 (separate grounds, passive input)
STO_IN_1A
DIG1_IN_1A
DIG3_IN_1A
CLK_OUT_1A
DIG_OUT_1A
DIG1_IN_2A
DIG3_IN_2A
CLK_OUT_2A
DIG_OUT_2A
+24V2
24V DC
0V
0V
GND24V2
DIG1_IN_1B
DIG3_IN_1B
CLK_OUT_1B
DIG_OUT_1B
DIG1_IN_2B
DIG3_IN_2B
CLK_OUT_2B
DIG_OUT_2B
DIG2_IN_1A
STO_IN_2A
DIG2_IN_2A
+24V1
GND24V1
STO_IN_1B
DIG2_IN_1B
STO_IN_2B
DIG2_IN_2B
BM5-O-SAF-00x-001-yyy
(x = 2,3)
GND_STO_IN_2
GND_STO_IN_1
GND_DIG2_IN_2
GND_DIG1_IN_2
GND_DIG1_IN_1
GND_DIG3_IN_2
GND_DIG3_IN_1
GND_DIG2_IN_1
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Emergency stop
device
Figure 60:
Connection diagram for the passive input
Summary of Contents for BM5-O-SAF-002