Assembly and installation
Operation Manual
Safety Module for b maXX 5000
BM5-O-SAF-002/3
Document no.: 5.11016.03
123
15
The standard EN 60 204-1 (Electrical Equipment of Machines) must be observed when
installing and mounting cable connections.
Further notes:
h
Make sure that the connection cable is routed in an EMC-compatible manner.
h
Use appropriate cables with an appropriate cable cross section.
h
Mark the cable connections, in order to protect against polarity reversals.
h
Ensure, that the connection plugs cannot fall out.
15.4.2 Requirements on the connection cable
The connection cable must be selected in accordance with the EN 60204-1 standard.
The Safety Module is equipped with plugged connectors at delivery (2 pieces with 18
poles respectively, part number 00351525 per connector) for the connection of the
conductors. These connectors must be plugged always in operation, even if a conductor
is not connected.
Connectable conductors must observe to the following characteristics:
Terminal range, rated connection:
min. 0.08 mm², max.1 mm²
Conductor connection cross section AWG: min. AWG 28, max. AWG 18
Single-wired/flexible:
min. H05(07) V-U 0.2 mm²,
max. H05(07) V-U 1 mm²
With wire end ferrule in accordance with DIN 46 228/1:
min. 0.13 mm², max. 0.34 mm²
With AEH with shroud DIN 46 228/4:
min. 0.13 mm², max. 0.34 mm²
on page 98 when connecting the brakes to the
basic unit.
Summary of Contents for BM5-O-SAF-002
Page 181: ......