4
Hardware configuration controller
BM5XXX - XXXX - XXXX - XX
XX
- XX - XXXX - EXX
01:
BSCsafe Step 1 V.1 (for single and double axis),
with AIO, DIO, encoder, EtherCAT® (RJ45)
02:
BSCsafe Step 1 V.2 (for single axis),
with AIO, DIO, encoder, EtherCAT® (RJ45)
04:
BSCsafe Step 1 V.4 (for active mains converter),
without AIO, without encoder evaluation, without add-on module
05:
Reserved
06:
BSCsafe Step 1 V.1 (for single and double axis),
with AIO, DIO, encoder, EtherCAT® (RJ45), with addi24 V supply for DIO and motor brake
07:
BSCsafe Step 1 V.4 (for active mains converter),
without AIO, without encoder evaluation, without add-on module, with addi24 V supply for DIO
08:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX), with AIO, DIO, encoder, fieldbus (RJ45)
09:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, encoder, fieldbus (RJ45), without DIO
10:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX)
with AIO, DIO, encoder, fieldbus (RJ45), both pulse enables are switched-on permanently
28:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, DIO, encoder, fieldbus (RJ45), 450 MHz
29:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, encoder, fieldbus (RJ45), without DIO, 450 MHz
30:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, DIO, encoder, fieldbus (RJ45), 450 MHz, both pulse enables are switched-on permanently
31:
Reserved
58:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX), with AIO, DIO, encoder, fieldbus (M8)
59:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, encoder, fieldbus (M8), without DIO
60:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, DIO, encoder, fieldbus (M8), both pulse enables are switched-on permanently
61:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with fieldbus (M8), DIO (but 4 normal digital inputs only, 2 of them for pulse enable),
without AIO, without 2nd encoder
62:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with fieldbus (M8), without AIO, without DIO, without 2nd encoder
80:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with AIO, DIO, encoder, fieldbus (M8), 450 MHz, both pulse enables are switched-on permanently
81:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with fieldbus (M8), DIO (DIO (but 4 normal digital inputs only, 2 of them for pulse enable), 450 MHz,
without AIO, without 2nd encoder
82:
BSCsafe Step 2 (for BM53XX, BM55XX, BM56XX, BM57XX),
with fieldbus (M8), 450 MHz, without AIO, without DIO, without 2nd encoder
Software option SoftDrivePLC
BM5XXX - XXXX - XXXX - XXXX - XX - XXXX -
EXX,
and XX > 01
Safety Level
BM5XXX - XXXX - XXXX - XXXX - XX - XXXX - [EXX] -
#XX
Mounting position of b maXX 5000
BM5XXX - XXXX - XXXX - XXXX - XX - XXXX - [EXX] - #XX -
[M0]
,
M0: Mounting position turned by 180°