Installation
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
175
7
7.15.3 Front side axis units BM53XX
Type code:
BM53XX-XXXX-XXXX-XX
01
or XX
06
X1
: Service interface
NOTE!
Only the service cable BM5-K-USB-XXX is
allowed to be used for the service interface X1,
refer to
X2
Digital inputs/outputs
*)
1
:see
2
to
3
: BB1 On (SELV/PELV)
4
to
7
: Digital output (SELV/PELV)
8
: see
9
to
10
: BB2 On (SELV/PELV). double axis
11
: +24V (SELV/PELV)
12
: M24V (SELV/PELV)
13
: Fast digital input 1 (SELV/PELV)
14
: Fast digital input 2 (SELV/PELV)
15
to
18
: Digital input (SELV/PELV)
19
: Digital input 7
20
: Digital input 8/ pulse enable 1
1 11
10 20
BM53XX-XXXX-XXXX-
01
XX
and
BM53XX-XXXX-XXXX-
07
XX
X3
EtherCAT
®
-IN
X4
EtherCAT
®
-OUT
BM53XX-XXXX-XXXX-
02
XX
X3
VARAN-IN
X4
VARAN-OUT
BM53XX-XXXX-XXXX-
03
XX
X3
CANopen
®
-IN
X4
CANopen
®
-OUT
BM53XX-XXXX-XXXX-
04
XX
X3
POWERLINK
®
-IN
X4
POWERLINK
®
-OUT
1
: TX+
2
: TX-
3
: RX+
6
: RX-
4
,
5
,
7
,
8
: reserved
A:
Assembly opening additional module
The delivery status is: empty
The operation is only permitted / possible with
an additional module BM5-O-SAF-XXX
(Mounting see manual 5.09013 and/or
5.11016)
It is not allowed to plug any other modules in!