![Baumuller b maXX 5000 Instruction Handbook Manual Download Page 55](http://html.mh-extra.com/html/baumuller/b-maxx-5000/b-maxx-5000_instruction-handbook-manual_2711361055.webp)
Technical data
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
55
3
3.3.5.4 Correction values DC link voltage
Mains rectifier
BM503X,
BM504X,
BM517X,
BM519X
With the permissible continuous DC link power, the power supply current, e.g. with a
power supply voltage of 480 V
AC
, is less by a ratio
400
480
----------
0 833
=
(instead of 31 A
AC
the power supply current is then 25.8 A
AC
).
When selecting the connected axes ensure that the DC link power is not exceeded.
D
C
link power
[%]
Power supply voltage [V]
Figure 27:
Derating: DC link power B503X, BM504X, BM517X, BM519X
Axis units
BM53XX
The axis units supply the rated/peak currents at rated DC link voltage. The output currents
must be reduced accordingly when operating with a DC link voltage is higher than 640 V
and output power remains constant.
Output curr
ent [%]
DC link voltage [V]
Figure 28:
Derating: Output current as function of the DC link voltage axis units