11
speedtec
®
M23
Follow the instructions below if a self-made cable with speedtec
®
M23 is to be used:
1
Utilize the following materials:
m
Cable: 4x0,38 + 1x(4x0,14)
m
High-density D-sub connector: 26-pin, male
m
Round connector: 9-pin speedtec
®
M23, female (Intercontec)
2
Fully adjoin the cable shield with the housing of the round connector and with the
shielding of the D-sub connector.
Figure 112:
Connecting cable for encoder with EnDat
®
2.2 speedtec
®
M23
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable is not functionally operable and could
lead to defects, both in the encoder module and the encoder!