7.15
Type code:
from BM53XX-XXXX-XXXX-XX
08
X1
: Service interface
NOTE!
Only the service cable BM5-K-USB-XXX is allowed
to be used, see
X2:
Digital inputs/outputs *)
1
:+24V (SELV/PELV)
2
to
3
: BB1 On (SELV/PELV)
4
to
7
: Digital output (SELV/PELV)
8
: M24V (SELV/PELV)
9
to
10
: BB2 On (SELV/PELV)
11
: +24V (SELV/PELV)
12
: M24V (SELV/PELV)
13
: Fast dig. input 1 (SELV/PELV)
14
: Fast dig. input 2 (SELV/PELV)
15
to
18
: Digital input (SELV/PELV)
19
: Dig. input 7/ pulse enable 2
20
: Dig. input 8/ pulse enable 1
1 11
10 20
B:
Add-on module (option) - not pluggable
BM53XX-XXXX-XX
00 -
no add-on module
BM53XX-XXXX-XX
01
Add-on module IEE with external supply
BM53XX-XXXX-XX
03
Add-on module SIE with internal supply
Refer to
BM53XX-XXXX-XXXX-
01
XX
and
BM53XX-XXXX-XXXX-
07
XX
X3
EtherCAT
®
-IN
X4
EtherCAT
®
-OUT
BM53XX-XXXX-XXXX-
02
XX
X3
VARAN-IN
X4
VARAN-OUT
BM53XX-XXXX-XXXX-
03
XX
X3
CANopen
®
-IN
X4
CANopen
®
-OUT
BM53XX-XXXX-XXXX-
04
XX
X3
POWERLINK
®
-IN
X4
POWERLINK
®
-OUT
1
: TX+
2
: TX-
3
: RX+
6
: RX-
4
,
5
,
7
,
8
: reserved
A:
Assembly opening additional module
The delivery status is: empty
The operation is only permitted / possible with an
additional module BM5-O-SAF-XXX (Mounting see
manual 5.09013 and/or 5.11016)
It is not allowed to plug any other modules in!