![Baumuller b maXX 5000 Instruction Handbook Manual Download Page 67](http://html.mh-extra.com/html/baumuller/b-maxx-5000/b-maxx-5000_instruction-handbook-manual_2711361067.webp)
BM5
331
BM5
331-A
BM5
332
BM5
332-A
BM5
333
BM5
333-A
Input rated power
1) 9)
13.4 kW
22.4 kW
33.6 kW
DC link voltage (U
DC
)
1)
60 V - 760 V
DC link capacitance (internal)
330 µF
660 µF
1175 µF
DC link discharge time
(internal DC link capacitance)
240 s
480 s
900 s
Output voltage
(U
AC
)
1) 3)
0 - 500 V
Output frequency at 4 kHz
4)
0 - 450 Hz
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
4 kHz
4)
2 x 12 A
2 x 20 A
2 x 30 A
2 x 28 A with UL
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
8 kHz
4)
2 x 8.4 A
2 x 14 A
2 x 21 A
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
16 kHz
4)
2 x 4.8 A
2 x 8 A
2 x 12 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
4 kHz
4)
2 x 24 A
2 x 40 A
2 x 60 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
8 kHz
4)
2 x 16.8 A
2 x 28 A
2 x 42 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
16 kHz
4)
2 x 9.6 A
2 x 16 A
2 x 24 A
Short-time operation KB
200 %
Max. length of time peak current
6)
Load cycle according EN61800-6
Power loss with regard to power supply
Max. 210 W
Max. 310 W
Max. 460 W
Power loss with regard to control voltage
supply (air-cooled)
7)
Max. 42 W
Max. 55 W
Power loss with regard to control voltage
supply (cold plate cooling)
7)
Max.
39 W
-
Max.
39 W
-
Max.
39 W
-
Current of the integrated
brake control
(option)
8)
Max. 2 x 2,0 A
Cooling air requirement power heat sink 55 m
3
/h
-
55 m
3
/h
-
100 m
3
/h
-
Cooling air velocity power heat sink
-
> 5 m/s
-
> 5 m/s
-
> 5 m/s
Cooling air requirement internal space of
device
10 m
3
/h
-
10 m
3
/h
-
10 m
3
/h
-
Technical data
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
67
3
Footnotes refer to