BM5030 with Safety Function
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
309
B
BM50XX-XX21
A normally closed contact is expected on the inhibit input.
Power supply
M24V
Inhibit input +24V
nc
Reset +24V
Error
Ready-to-operate
DC link connection
to further devices
Connection for
STO function
NOTICE
:
Pay attention to the max.
connectable DC link
capacitance connected
downstream
STO
,
see Technical Data.
Connection for additional
DC link capacitance connected
upstream STO
,
e.g. BM5-CAP
Figure 129:
Connection diagram BM5030-XX21-...
1C1, 1D1
Connections for the DC link
PE
Power supply PE-connection
1U1, 1V1, 1W1
Power supply connection
F1
Fuses (cable + device)
Z1
Line filter
K1
Main contactor (option)
X200
Connections for 24 V voltage supply
X1
Control inputs and outputs
X2
Connections of STO function
X101
Connection for additional DC link capacitance, e. g. BM5-CAP