69
6.4 Replacement Encrypted Coin mech set up
Following the installation of the new Encrypted SR3e coin mech and executive software, any
future coin mech failures that result in a replacement mech having to be fitted must have the
encryption key reset prior to installation.
Encrypted SR3e coin mechs that have been initialised within a Triple 7 machine cannot be
swapped into another machine, unless the encryption key has been reset.
New replacement SR3e coin mechs with the encryption key reset are available from Barcrest
Aftersales.
From the ‘MAIN MENU’ select the ‘SERVICE’ button
as shown in the image below and enter the
service menu by confirming via the internal IButton.
Select ‘SERIAL DEVICES SET UP”
from the
‘SERVICE MENU’
as described in section 5.15.
A Button will now be displayed in the centre of
the screen saying “Coin Mech initialisation
complete press ok to reboot”
. When selected the machine will now reset.
Once the machine has initialised select the ‘SERVICE’ button from the ‘MAIN MENU’ screen
and test the new Encrypted SR3e
Coin Mech in ‘VALIDATOR TEST’ to ensure it is functioning
correctly. If the mech fails set up then repeat the procedures listed in this section.
6.5 Serial Devices Set up
To set up the coin mech or note acceptor, enter the main menu and then select the serial
devices button as indicated below.