www.baldormotion.com
3-16 Basic Installation
MN1942
3.4.7 Power supply filters
To comply with EEC directive 89/336/EEC, an AC power filter of the appropriate type must be
connected. This can be supplied by Baldor and will ensure that the MicroFlex
e
100 complies with
the CE specifications for which it has been tested. Ideally, one filter should be provided for each
MicroFlex
e
100; filters should not be shared between drives or other equipment. Table 4 lists the
appropriate filters:
MicroFlex
e
100
current
Input voltages
current
rating 230 VAC, 1
Φ
230 VAC, 3
Φ
3 A
FI0 line reactor
(see sections 3.4.7.1 and 3.4.7.2)
or
FI0029A00 (see section A.1.2)
FI0018A00
6 A
FI0015A02 (see section 3.4.7.2)
or
FI0029A00 (see section A.1.2)
FI0018A00
9 A
FI0029A00 (see section A.1.2)
FI0018A03
Table 4 - Baldor filter part numbers
Maximum earth leakage from the MicroFlex
e
100 is 3.4 mA per phase (230 V, 50 Hz supply).
This value does not include the earth leakage from the AC power filter, which could be much
larger (see section A.1.4).
3.4.7.1 Harmonic suppression
When operating the 3 A MicroFlex
e
100 (part MFE230A003) on a single-phase AC supply, a
13 mH, 4 A
rms
(10 A peak) line reactor is required to ensure compliance with EN61000-3-2:2000
class A limits, when the total equipment supply load is less than 1 kW.
3.4.7.2 Reversing the filter
When using filters FI0015A00 or FI0015A02 as specified in Table 4, they must be reversed to
ensure that the MicroFlex
e
100 complies with the CE specifications for which it has been tested.
The AC power supply should be connected to the filter terminals marked as the outputs, with the
MicroFlex
e
100 connected to the filter terminals marked as the inputs.
This recommendation applies only to filters FI0015A00 and FI0015A02.
Alternative filters or protection devices must be connected as specified by the
manufacturer.
WARNING
Summary of Contents for MicroFlex e100
Page 1: ......
Page 2: ......
Page 14: ...www baldormotion com 2 4 Introduction MN1942...
Page 80: ...www baldormotion com 5 26 Input Output MN1942...
Page 108: ...www baldormotion com 6 28 Configuration MN1942...
Page 116: ...www baldormotion com 7 8 Troubleshooting MN1942...
Page 124: ...www baldormotion com 8 8 Specifications MN1942...
Page 142: ...www baldormotion com B 6 Control System MN1942...
Page 170: ...Comments MN1942 Thank you for taking the time to help us...
Page 171: ......
Page 172: ......