www.baldormotion.com
4-4 Feedback
MN1942
4.1.1.2 Encoders without Halls
Incremental encoders without Hall feedback connections may be connected to the
MicroFlex
e
100. However, if Hall connections are not present, it will be necessary for the
MicroFlex
e
100 to perform an automatic phase search sequence each time it is powered. This
will cause motor movement of up to 1 turn on rotary motors, or one pole-pitch on linear motors.
CHA+
CHA-
CHB+
CHB-
+5 V out
DGND
1
9
2
10
3
11
12
X8
CHZ+ (INDEX)
CHZ- (INDEX)
13
4
Sense
Connect overall shield
to connector backshells.
Twisted pairs
Encoder
Feedback
Motor
Figure 15 - Encoder cable connections without halls - rotary motors
4.1.1.3 Halls-only feedback devices
Feedback devices using only Hall sensors may be connected to the MicroFlex
e
100. However,
since there are no encoder connections, the MicroFlex
e
100 will not be able to perform smooth
speed control or accurate positioning control.
+5 V out
DGND
12
X8
6
5
15
14
8
7
13
Hall U+
Hall U-
Hall W+
Hall W-
Hall V+
Hall V-
4
Sense
Hall
Feedback
Connect overall shield
to connector backshells.
Motor
Figure 16 - Halls-only feedback cable connections - rotary motors
Note:
If the Hall inputs are used as single ended inputs, leave the Hall U-, Hall V- and
Hall W- pins unconnected; do not connect them to ground.
Summary of Contents for MicroFlex e100
Page 1: ......
Page 2: ......
Page 14: ...www baldormotion com 2 4 Introduction MN1942...
Page 80: ...www baldormotion com 5 26 Input Output MN1942...
Page 108: ...www baldormotion com 6 28 Configuration MN1942...
Page 116: ...www baldormotion com 7 8 Troubleshooting MN1942...
Page 124: ...www baldormotion com 8 8 Specifications MN1942...
Page 142: ...www baldormotion com B 6 Control System MN1942...
Page 170: ...Comments MN1942 Thank you for taking the time to help us...
Page 171: ......
Page 172: ......