www.baldormotion.com
Input / Output 5-5
MN1942
5.2.2 General purpose digital input DIN0
Location
Connector X3, pins 7 & 17
(Mating connector: Weidmüller Minimate B2L 3.5/20)
Name
DIN0
Description
General purpose opto-isolated digital input.
Nominal input voltage: +24 VDC
(input current not to exceed 50 mA)
Sampling interval:
1 ms
This general purpose digital input is buffered by a TLP280 opto-isolator, allowing the input signal
to be connected with either polarity. The state of the digital input is displayed in the Mint
WorkBench Spy window. The input can be can be configured for different user definable
functions.
DIN0+
3k3
TLP280
DGND
Mint
Vcc
MicroFlex
e
100
DIN0-
100R
74LVC14
17
7
Figure 29 - General purpose digital input circuit
When the MicroFlex
e
100 is connected to Mint WorkBench, the digital input can be configured
using the Digital I/O tool. Alternatively, Mint keywords including
RESETINPUT
,
ERRORINPUT
and
STOPINPUT
can be used in the command window. The state of the digital input can be
viewed using the Mint WorkBench Spy window’s Axis tab. See the Mint help file for details.
7
17
Summary of Contents for MicroFlex e100
Page 1: ......
Page 2: ......
Page 14: ...www baldormotion com 2 4 Introduction MN1942...
Page 80: ...www baldormotion com 5 26 Input Output MN1942...
Page 108: ...www baldormotion com 6 28 Configuration MN1942...
Page 116: ...www baldormotion com 7 8 Troubleshooting MN1942...
Page 124: ...www baldormotion com 8 8 Specifications MN1942...
Page 142: ...www baldormotion com B 6 Control System MN1942...
Page 170: ...Comments MN1942 Thank you for taking the time to help us...
Page 171: ......
Page 172: ......