7.10 Automatic backflushing
The control system is adapted to the BADU Omni actuating drive
at the factory. It must be backflushed first when the filter is used
for the first time.
Two different types of operation can be selected:
•
Automatic
•
Winter operation
Backflushing runs automatically under “Automatic” operation and
the interval function. After switching on the control system, the
BADU Omni actuating drive runs an initialisation sequence first.
The “Valve position” display field shows the current position of the
valve.
A manual backflushing cycle can be started under Manual Start.
This changes the times for “Next automatic backflush” and “Last
backflush”. The time for “next automatic backflush” is always
adapted to the set backflush intervals.