Installation
14 EN
09|2019
5.2.1 Terminal assignment plan
Operating voltage: 230 V, 50/60 Hz
Fixed wiring is necessary for permanent operation!
Assignment of the output relay RasPl
Motherboard:
Relay 1 (X7:1/2/4)
Level
potential-free
Relay 2 (X7:11/12/14)
Attraction 1
potential-free
Relay 3 (X7:21/22/24)
Attraction 2
potential-free
Relay 4 (X6:5)
Attraction 3
Relay 5 (X6:4)
Floor drain ball valve
Relay 6 (X6:3)
Heating
Relay 7 (X6:2)
Redox dosing pump
Relay 8 (X6:1)
pH dosing pump
Daughterboard:
Relay 1
n1
NO (normally open)
Relay 2
n2
NO (normally open)
Relay 3
n3
NO (normally open)
Relay 4
Stop
NC (normally closed)
If a normal AC pump is installed instead of a speed-controlled
pump, the pump must be connected to relay 4 (Stop) as a closer
(NO).