Operation
09|2019
EN 33
The controller type can by set by the Parameters button at the
bottom of the screen. The deviation of the filter pump and the
safety cut-out in minutes can also be controlled here.
7.6.1 Redox filter pump max control deviation
The control deviation can be set in the redox parameters. The
values are between 100 and 600. The function can be deactivated
with “Off”. The control deviation is suppressed for 1 minute to
avoid oscillations. If the nominal value is greater than the actual
value, the redox display turns yellow and shows “Limit”. The filter
pump switches to stage 3 at control deviation (when nominal
value > actual value) and the filter pump display shows “Forced-
ON-Stage-3”. If the deviation “Off” is selected, the function is
ignored.