09|2019
When the filter pump switches on due to the set filter time, a delay
time runs so that the pH, redox and pool water temperature
values can be updated based on standing water.
•
Delay time pH: 8 minutes
•
Delay time redox: 8 minutes
•
Delay time heating: 30 seconds
The delay for heating is only active in the “Heating” and “Thermal
heat pump” operating modes.
The “Solar” operating mode has no delay because solar has a
priority function.