Operation
09|2019
EN 49
4. Select speed stage (possible here).
5. Manual backflushing.
7.10.4 Using a Besgo rod valve
The rod valve type must be selected in the “Valve position” -
“Parameters” field.
The BADU Omni actuating drive sends an enable signal to the
control system in the moved to positions. This signal must be
bridged when a rod valve is used.
Wire bridge (12V):
From terminal X2:3 to input I06
The rod valve must then be connected to relay 5 of the
daughterboard for backflushing.
The duration of the backflushing process can be set in the
switching times.