Operation
48 EN
09|2019
7.10.1 Setting the backflush interval
Basically, 3 different backflush intervals can be set:
•
Off
•
Days 1 … 30
•
Mo, Tu, We, Th, Fr, Sa, Su
Any time can be set. The backflushing then starts automatically
depending on the set time. The two settings backflush interval and
time are defined by the “Set interval” command.
7.10.2 Setting adjustment times
The duration for the backflushing time and the rinsing time can be
defined in minutes and seconds under Adjustment times.
7.10.3 Manual backflush valve
Take the following steps if a manual backflush valve is installed:
1. Wire bridge (12 V), from terminal X2:3 to input I06
2. Backflush interval on “Off”.
3. Filter pump manual operation.