Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-100
an error displays and the system does not run.
When/How to Use
This parameter is enabled, if required, when the Integrator
utility is run for the switch.
Make sure the sentinel supports Serial integration, and you
installed the supporting program before attempting to launch
the Octel 50 system.
Related Parameters/Features
You must set the Init Mode parameter to C for all ports on
which you are using communications message waiting light
software.
If you enable this parameter, the Permit Message Waiting
Lights parameter must be enabled, and you can configure
the Light Message Waiting Lights for Every Message
parameter as you like. However, the remaining Message
Waiting Light parameters must be blank and disabled.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
–
Max
–
Default
No
Requires
Restart
Yes
Switch-
Dependent
Yes
Set by
Integrator
Yes
Simplified Message Desk Interface Parameters - #190
Strobe Interval in
Seconds
(STROBE)
This parameter specifies the number of 10 millisecond
intervals that a signal is sent to the switch configured with
SMDI to notify the switch that voice mail is running.
When/How to Use
The default should be sufficient for most Octel 50 systems.
Related Parameters/Features
The Use SMDI parameter must be enabled for this
parameter to be used.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
999
Default
0
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Low-Level Voice Board Parameters
The Low-Level Voice Board parameters are set when you run Call Analysis. Do not
modify these parameters unless you areinstructed to by a technical support
representative to change them.