Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-61
Related Parameters/Features
Dial Plan is only used when the destination number exceeds
the Number of Digits in Local Telephone Number.
The Octel 50 system only uses the Code for Accessing an
Outside Line for numbers that are equal to or greater than
the length of Number of Digits in Local Telephone Number.
The Custom Message Delivery Code is used for message
and fax delivery when the length of the destination number
is less than the Number of Digits in Local Telephone
Number.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
9
Default
7
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No
Dialing Parameters - #114
Number of Rings
Before No
Answer (RINGS)
This parameter defines the number of rings the Octel 50
system will listen to before assuming a no answer. This
parameter is only used for outdial operations.
When/How to Use
The default should be adequate for most Octel 50 systems.
However, if you find that the switch is routinely pulling calls
back, try lowering this parameter.
Related Parameters/Features
This parameter is only used if the Octel 50 system is
supervising calls.
The Maximum Rings field on the Class of Service dialog
box, which controls the number of rings that are considered
a no answer for both outcalls and internal transfers, can
override this parameter on a class of service basis.
Do not confuse this parameter with the Number of Incoming
Rings (INRINGS). The Number of Incoming Rings
(INRINGS) determines the number of rings each port must
hear before it answers an inbound call.
If Set Too High
If you set this parameter higher than the number of rings the
switch regards as a no answer, the call might go back to the
switch.
If Set Too Low
Call progress may fail.
Min
0
Max
99
Default
5
Requires
Restart
No
Switch-
Dependent
No
Set by
Integrator
No