Setting Up the System
Configuring System Setup Parameters
Octel 50 Installation Guide
8-76
Inband Code for Go to Immediate Transfer to Extension
The Inband Code for Go to Immediate Transfer to Extension parameters configure the
Octel 50 system to transfer callers to subscriber extensions.
When the Integrator utility is run, the Octel 50 system enters default settings for the codes
required by the switch. These settings are determined based on default settings for the
switch. If you or the manufacturer modify the switch programming or features, integration
may be affected. If this occurs, call a technical support representative.
Inband Code for Go to Immediate Transfer to Extension Parameters - #141
Inband Code
String
This parameter specifies the code sent by the switch that
instructs the Octel 50 system to transfer the call directly to
the mailbox that follows the code.
When/How to Use
When this code is used, the caller hears,
“Please hold for
<mailbox owner’s name prompt>.”
The Octel 50 system automatically sets this parameter when
the Integrator utility is run. You should not need to change
it.
Related Parameters/Features
The Location of Inband Signaling Code parameter specifies
where this code is located in an incoming inband string.
The minimum and maximum for this parameter refer to the
length of the entry allowed, not an actual number.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.
Min
0
Max
32
Default
Blank
Requires
Restart
No
Switch-
Dependent
Yes
Set by
Integrator
Yes
Inband Code for Go to Immediate Transfer to Extension Parameters - #142
Location of
Mailbox Number
This parameter specifies which digit in the string for Go to
Immediate Transfer to Extension is the first digit in the
mailbox number that follows the code.
When/How to Use
The setting of this parameter depends on whether the count
starts from the beginning or the end of the string.
Related Parameters/Features
The Location of Mailbox Number and the Start at the End of
String parameters work together. For example, if the
incoming string is 9*1123 and the mailbox number is 123,
the Number of DID Digits to use is 6, the DID Code is 9*1,
the Location of Inband Signaling Code is 1, and, if Start at
End of String is set to Yes, the Location of Mailbox Number
is 3. If Start at End of String is set to No, the Location of
Mailbox Number is set to 4.
If Set Too High
Not applicable.
If Set Too Low
Not applicable.