Page 60 - Ferrograph Wallboard 10
Wallboard Installation & Maintenance
Baud Rate
The Baud Rate can be changed to 1200, 2400, 9600 or 19200 using the dip-switch.
The Baud Rate is set using switches 5 and 6.
5 6
Baud
Rate
ON ON 1200
OFF ON 2400
ON OFF 9600
OFF OFF 19200
Ensure the Baud rate is set to 9600.
Test Functions
Test functions are provided to assist installation engineers. These are selected on the
dips-witches. Test functions are selected using switches 7 and 8.
If switch 7 and 8 are
OFF
at power reset:
7 8
ON ON
Freeze
Display
OFF
ON
Alternating ON/OFF Blocks
of LED's
ON OFF
Stripes
OFF OFF
Normal
Operation
If switch 7 and 8 are
ON
at a power reset:
7 8
ON ON
Information
Screen
OFF ON Stripes
ON
OFF
Alternating ON/OFF Blocks
of LED's
OFF OFF
Freeze
Display