Chapter 12: Trunk Configuration
MAXCS ACC 6.0 Administration Manual 157
Incoming Ring
Single
—Default setting for North America
Double
—For countries using Ring-Ring-Silent type of ring
pattern
Impedance
The resistance of electrical current to alternating current,
measured in Ohms. Impedance occurs when power or
signal is transferred from one circuit to another. When a
trunk interface impedance is greatly mismatched with the
CO analog line, it may result in static noise and echo heard
by IP phone users. The system automatically selects the
impedance profile that best matches the Triton trunk
interface with the CO. In the rare case where you are not
getting the best match, you can disable this feature by
checking
Disable Impedance Match During System
Startup
, and you can set the
Impedance
manually.
Match Impedance
button
Changes the
Impedance
setting to the best match for the
selected trunk channel, and then measures noise and
returned echo with this impedance setting. Results are
displayed in the Diagnosis section of the dialog box. The
system automatically runs a matching test upon system
startup, unless you disable the feature. If later you
connect a new analog line to an empty port or replace an
existing line, you need to click this button to best match
the impedance.
Match Result button
Shows the result obtained the last time the
Match
Impedance
button was clicked for that trunk.
Disable Impedance
Match During System
Startup
Check to disable automatic impedance matching during
system startup.
Caller ID Receiving
Select as
None
,
FSK
or
DTMF
for receiving caller ID
digits. For North America, the caller ID is FSK signal on
analog trunk.
Centrex Flash
Duration (ms)
Specifies the Flash Duration time in milliseconds, with a
range from 150 ms to 1000 ms.
Out of Service With
Trunk Seizure
When checked, if the trunk is set to
Out of Service
, the
system will busy out the trunk. The CO will treat this trunk
as a busy line and WILL NOT place a call to this trunk. (By
default, this option is unchecked.)
Enable Dial Tone
Detection (Outgoing)
When enabled, the trunk channel must detect outgoing
dial tone prior to making the call.
Enable Answer
Debounce (Incoming)
Enables a timeout period of 2 seconds (for ignoring false
CO disconnect signal), after answering an incoming call.
Loop Break Duration
(ms)
Disconnects signal if CO breaks loop current. You can set
the duration from 200 to 1000 ms. 600 ms is common in
North America.
Parameter
Description
Summary of Contents for MAX Communication Server ACC 6.0
Page 1: ...MAX Communication Server Administration Manual ACC 6 0 Update 1 1 2009 4413 0001 6 0 Update 1...
Page 14: ...xii MAXCS ACC 6 0 Administration Manual...
Page 16: ...2 MAXCS ACC 6 0 Administration Manual...
Page 34: ...Chapter 1 Overview 20 MAXCS ACC 6 0 Administration Manual...
Page 98: ...Chapter 6 Voice Mail Configuration 84 MAXCS ACC 6 0 Administration Manual...
Page 124: ...Chapter 9 Call Recording Configuration 110 MAXCS ACC 6 0 Administration Manual...
Page 128: ...Chapter 10 Application Extension Configuration 114 MAXCS ACC 6 0 Administration Manual...
Page 186: ...Chapter 13 In Call Routing Configuration 172 MAXCS ACC 6 0 Administration Manual...
Page 198: ...Chapter 14 Out Call Routing Configuration 184 MAXCS ACC 6 0 Administration Manual...
Page 230: ...Chapter 15 Extension Configuration 216 MAXCS ACC 6 0 Administration Manual...
Page 238: ...Chapter 16 Setting Up IP Extensions 224 MAXCS ACC 6 0 Administration Manual...
Page 254: ...Chapter 18 Mobile Extension Configuration 240 MAXCS ACC 6 0 Administration Manual...
Page 272: ...Chapter 20 Paging Group Configuration 258 MAXCS ACC 6 0 Administration Manual...
Page 276: ...Chapter 21 Line Park Configuration 262 MAXCS ACC 6 0 Administration Manual...
Page 298: ...Chapter 22 Workgroup Configuration 284 MAXCS ACC 6 0 Administration Manual...
Page 316: ...Chapter 24 Network Configuration Guidelines for VoIP 302 MAXCS ACC 6 0 Administration Manual...
Page 350: ...Chapter 25 Enterprise VoIP Network Management 336 MAXCS ACC 6 0 Administration Manual...
Page 370: ...Chapter 27 System Report Management 356 MAXCS ACC 6 0 Administration Manual...
Page 392: ...Chapter 28 Microsoft Exchange Integration 378 MAXCS ACC 6 0 Administration Manual...
Page 400: ...Chapter 29 TAPI Integration 386 MAXCS ACC 6 0 Administration Manual...
Page 439: ...MAXCS ACC 6 0 Administration Manual 425 UDP 10060 UDP 30 000 31 000 TCP 10064...
Page 440: ...426 MAXCS ACC 6 0 Administration Manual...