Chapter 26: Redundancy Configuration
MAXCS ACM 6.0 Administration Manual 339
•
The network of the active system disconnects, and
Automatically assume control
when active system is not available
is selected in the Redundancy dialog box of
the standby system (see Figure 2 on page 341).
How Calls Are Affected When Switchover Occurs
When system control switches from the active to the standby system, it affects calls in
the following ways:
•
A direct connected call is kept (except in the case of shutdown or restart), like
extension A calls extension B and is connected. All other calls are disconnected (for
example, conference calls; silent monitor, barge in and coaching calls; parked calls,
queued calls, and calls in music-on-hold; APC calls; paging). In voice mail, a
Zoomerang call is kept but you cannot go back to VM.
•
In those direct connected calls, if one or both sides uses an H.323 channel, it will be
reset after switching over. MAXCS 6.0 Update 1 redundancy supports:
•
Analog Ext/Trk to Analog Ext/Trk
•
Analog Ext/Trk to T1/E1/PRI
•
Analog Ext/Trk to SIP Ext/Tie/Trunk
•
T1/E1/PRI to SIP Ext/Tie/Trunk
•
SIP Ext/Tie/Trunk to SIP Ext/Tie/Trunk
•
Mobile Ext to Analog Ext/Trk
•
Mobile Ext to T1/E1/PRI
•
Mobile Ext to SIP Ext/Tie/Trunk
•
The connected trunk and extension channel shows "in use" in the standby Softswitch
until it is disconnected.
•
CDR is dropped for all calls, including connected calls.
•
Recording stops.
•
After switching, channels and extensions that were connected still have busy status,
and a call to these channels or extensions will follow busy call handling rules.
•
If a SIP channel is involved in a call, and a resource channel in the local gateway is
allocated, the call will not be kept.
•
After switchover, disconnection is the only action available to calls that remained
connected. (Users cannot transfer, conference, park, start recording, and so on.)
•
If a connected call does not hang up within 30 minutes after switchover happens,
the call is reset by the standby server. The value of timeout can be changed in the
registry. The path is "HKEY_LOCAL_MACHINE\SOFTWARE\AltiGen Communications,
Inc.\AltiWare", and the key name is "RedundCallConnectTimeout". After changing
the timeout value, you must restart the server to apply the change.
Requirements for Other System Components
This section lists firmware and software requirements.
Summary of Contents for MAX Communication Server ACC 6.0
Page 1: ...MAX Communication Server Administration Manual ACC 6 0 Update 1 1 2009 4413 0001 6 0 Update 1...
Page 14: ...xii MAXCS ACC 6 0 Administration Manual...
Page 16: ...2 MAXCS ACC 6 0 Administration Manual...
Page 34: ...Chapter 1 Overview 20 MAXCS ACC 6 0 Administration Manual...
Page 98: ...Chapter 6 Voice Mail Configuration 84 MAXCS ACC 6 0 Administration Manual...
Page 124: ...Chapter 9 Call Recording Configuration 110 MAXCS ACC 6 0 Administration Manual...
Page 128: ...Chapter 10 Application Extension Configuration 114 MAXCS ACC 6 0 Administration Manual...
Page 186: ...Chapter 13 In Call Routing Configuration 172 MAXCS ACC 6 0 Administration Manual...
Page 198: ...Chapter 14 Out Call Routing Configuration 184 MAXCS ACC 6 0 Administration Manual...
Page 230: ...Chapter 15 Extension Configuration 216 MAXCS ACC 6 0 Administration Manual...
Page 238: ...Chapter 16 Setting Up IP Extensions 224 MAXCS ACC 6 0 Administration Manual...
Page 254: ...Chapter 18 Mobile Extension Configuration 240 MAXCS ACC 6 0 Administration Manual...
Page 272: ...Chapter 20 Paging Group Configuration 258 MAXCS ACC 6 0 Administration Manual...
Page 276: ...Chapter 21 Line Park Configuration 262 MAXCS ACC 6 0 Administration Manual...
Page 298: ...Chapter 22 Workgroup Configuration 284 MAXCS ACC 6 0 Administration Manual...
Page 316: ...Chapter 24 Network Configuration Guidelines for VoIP 302 MAXCS ACC 6 0 Administration Manual...
Page 350: ...Chapter 25 Enterprise VoIP Network Management 336 MAXCS ACC 6 0 Administration Manual...
Page 370: ...Chapter 27 System Report Management 356 MAXCS ACC 6 0 Administration Manual...
Page 392: ...Chapter 28 Microsoft Exchange Integration 378 MAXCS ACC 6 0 Administration Manual...
Page 400: ...Chapter 29 TAPI Integration 386 MAXCS ACC 6 0 Administration Manual...
Page 439: ...MAXCS ACC 6 0 Administration Manual 425 UDP 10060 UDP 30 000 31 000 TCP 10064...
Page 440: ...426 MAXCS ACC 6 0 Administration Manual...