R01.43
22.10.2018
Page 93
5.6.2 Digital input/output
The control unit has eight 24V DC digital inputs and outputs. The following figure shows
an integration to a "customer device".
Figure 75: Digital IO Connection
In contrast to other fieldbus interfaces, the "load config #" command must be used
instead of the "load config number" command to load a configuration using the digital
IO.
Table 10: Digital IO Commands
Command name
Description
Load Config #1
Load Config #2
Load Config #3
Load Config #4
Load Config #5
In the control unit various aflex configurations can be stored.
This allows you to quickly switch between separating, con-
veying or alternatively changing configurations for different
work pieces.
With the commands Load Config #x, the corresponding con-
figuration is loaded with a rising flank. These commands al-
low you to load a configuration without using 8 bits for the
LoadConfigNumber command.
Because only eight digital inputs are available, the possibilities to integrate the aflex
are limited. Two different strategies are described in more detail below.
24V
Output
24V
Input
LED - actual
states
Control
Unit