R01.43
22.10.2018
Page 33
Series number (4)
The series number of the Controlunit. This can also be found on the housing, in the
side inscription field.
Network status, Subnet (5)
To establish a connection to the control unit, the two participants must be found in the
same subnet. If the status "different network" is displayed, the IP address of the com-
puter must be adapted to establish a connection.
Ping status (6) and Ping response time (7)
If both participants are found in the same subnet, the aflexConfigurator starts a ping
process to check the availability of the control unit. The status and the response time
are visualized in this line.
Save control unit (8)
Once detected control unit's can be stored for later use in a local file. If the aflexCon-
figurator is closed, all control unit's with the status "remember connection" are saved.
These are loaded when the program is restarted and added to the display. To prevent
older control unit's to display automatically, the checkbox "remember connection" has
to be removed.
Establish connection (9)
This button starts the connection set-up to the control unit.
The various views of the control unit display are visualized and described below.
Figure 16: Connection not possible, different subnet
The control unit and computers are located in different subnets. The IP address of the
computer must be adapted to establish a connection. In this example, click on the
"192.168.2.xxx" section.