R01.43
22.10.2018
Page 49
Select configuration (1)
A different configuration can be loaded in each sequence. If the same configuration is
used for the previous sequence, it is not reloaded. If no configuration is selected, there
is also no loading process.
Select direction (2)
A different direction of movement is given in each sequence. Entry is possible via slider
or textbox. Valid values: 0-360°, in case of false entry, the value is not accepted.
Select intensity (3)
A different intensity is given in each sequence. Entry is possible via slider or textbox.
Valid values: 0-100%, in case of false entry, the value is not accepted.
Select duration (4)
The duration of each sequence is defined by this slider. It should be noted that the
duration of all sequences is included in the calculation of the minimum pause time.
Entry is possible via slider or textbox. Valid values: 0-2500ms, in case of false entry,
the value is not accepted.
Pause time (5)
A pause time,in which the intensity is set to "0". Entry is possible via slider or textbox.
Valid values: 0-20000ms, in case of false entry, the value is not accepted. In order to
avoid over-heating of the aflex, it should be controlled by a relative switching duration
> 15%. If the pause time is too low, a warning and the necessary pause duration are
displayed.
Demo Name(6)
Name of the demo under which it is identified
Description (7)
This description is displayed when the demo is selected. A sensible description should
be chosen. A maximum of 100 characters is possible.
Export (8)
Export the simulation to a local file. Used to create backups or transfer simulations to
other computers.
Import (9)
Import a simulation in the aflexConfigurator. to use this.
Save (10)
Saves the simulation. When changing an existing demo, the user can decide whether
to overwrite it with the new values or generate a new demo. In the second case, how-
ever, the name should be adapted to facilitate identification. If the name does not