Page 24
22.10.2019
R01.43
Power supply
WARNING
▪
Work on the electrical supply may only be carried out by
trained, authorized qualified personnel!
▪
The grid feed must take place on the customer's side via a
residual current circuit breaker!
▪
The aflex may only be driven with 24V DC.
The energy feed of aflex takes place with 24V DC low-voltage. The energy supply must
be made available by the operator. The manufacturer recommends a 10 A slow fuse
or a circuit breaker of the C 10A characterization.
The exact specification is available in the chapter
The assembly may only be carried out by a qualified personnel.
Connection of the control
All modules of the control are mounted on a profile rail with BackSideBus.
The modules are fixed via end terminals and the terminating resistors of the BackSide-
Bus are thus protected. Below is a drawing of the controller. The profile rail is delivered
with a length of 142.0 mm, the BackSideBus with a length of 123.0 mm.
Figure 10: Drawing Control modules
The control is sent in the mounted state; it is possible to install the profile rail in the
control cabinet without dismantling. Alternatively, the control modules can be disman-
tled. For subsequent reassembly, observe the following procedure: