Figure 54: T4X Channel Node "Admin" view
(1)
Min/Max Power
(2)
Pulse Mode
Slider Min/Max Power (1)
The maximum intensity set by this slider, limits the controller intensity of the actuators.
The intensity is converted as a percentage to the maximum setting. If this is for e.g. set
to 80%, the actuator is only controlled at 80% with a control of 100%.
This function is necessary because the vibration plate is attached to the actuators and
is strongly inhibited if the controller power is too high. This is prevented by limiting the
maximum controller intensity. To compensate for manufacturing tolerances, this setting
can be set individually for each channel.
INSTRUCTION
The min/max power of the individual channels is already pre-set
in the delivery state and should only be adapted when an aflex
exchange is used.
Pulse Mode (2)
An aflex is always controlled with the "Pulse Mode Continuous" during operation. In
this mode, each actuator is pulsed with the set frequency and channel phase.
Alternatively, the mode "Pulse Mode Off" can be used to determine the position of an
actuator. The actuator is switched over to continuous operation. If the T4X client node
is linked to an aflex software module, this setting is automatically overwritten when the
aflex is controlled.
INSTRUCTION
If an aflex is connected to this channel, the maximum duty cycle
of the actuators must be observed. This is specified in the tech-
nical data of the aflex.