Tabelle 23:
Profinet LED „nwstate“
nwstate LED
description
comment
off
Offline
No network connection
green on
Online (Run)
Connection to IO Controller established. IO
controller in RUN state
green flash
Online (Stop)
Connection to IO Controller established. IO
controller in Stop.
green blink
Blink
Identification blink code. Activated from exter-
nal tool for identification of the device.
red on
Internal error
Unexpected internal error
red, flashes
once
error station
name
No station name assigned
red, flashes
twice
error IP address No ip address assigned
red, flashes
thrice
Error communi-
cation
Expected configuration differs to actual config-
uration
Tabelle 24: Profinet X2/X3
X2 / X3 LED
description
comment
off
No link
X2/X3 not connected. No communication.
on
Link
Ethernet connected, no traffic
blink
Activity
Ethernet connected, traffic identified
7 Maintenance instructions
INSTRUCTION
The aflex is maintenance-free.
If repair or maintenance is still required, please contact the aflex
manufacturer.