Sensor Installation and Connection
3-5
Flow Traveling at Least One Foot Per Second
Slower
flows enable debris to settle in the pipe, limiting the accuracy
of flow measurements.
Higher Elevation than High Water Level that Occurs
in Wet Well at Downstream Pump Station
Pipes that are
below the high water level of the pump station wet well could
experience frequent backup and surcharging. This will increase
sensor maintenance and possibly reduce data accuracy.
Pipe and Manhole Characteristics
The physical characteristics of the pipe affect the flow and
determine the procedure for installing the sensors. Consider the
following factors and perform the following activities when
installing the sensors and monitor:
Sensor Installation Method
Pipe size and shape determine
the installation method to employ for installing the sensors.
Standard Installation
Select this option to install
sensors in
round
pipes from 8 inches (200 mm) to 48
inches (1219 mm) in diameter. Standard installations
involve attaching sensors to an adjustable stainless steel
ring that mounts inside the pipe.
Special Installation
Select this option to install sensors
in non-round pipes or round pipes larger than 48 inches.
(1219 mm) in diameter.
Special installations involve
attaching sensors to steel bands secured to the inside of the
pipe.
Pipe Height and Width
Measure and record the horizontal
and vertical pipe dimensions carefully. Inaccurate pipe
measurements—even slightly inaccurate measurements--can
skew and misrepresent flow data.
Summary of Contents for Intrinsically-Safe TRITON+
Page 19: ...1 12 ADS TRITON Manual Control Drawing ...
Page 25: ...1 18 ADS TRITON Manual First page of the TRITON ATEX Certificate ...
Page 27: ...1 20 ADS TRITON Manual First page of the TRITON IECEx Certificate of Conformity ...
Page 29: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 1 ...
Page 30: ...Introduction 1 23 CSA Certificate of Compliance Page 2 ...
Page 32: ...Introduction 1 25 Sample TRITON Declaration of Conformity Page 2 ...