Specifications
A-5
Intrinsically-Safe Sensors
Peak Combo Sensor (ADS p/n 8K-CS4-xx-35/1H)
This sensor supports upward ultrasonic depth, peak velocity, and
pressure depth.
Enclosure
ABS plastic shell, epoxy-filled
Dimensions
Enclosure: 6.76 inches (172 mm) long x 1.23
inches (31 mm) wide x 0.83 inches (21 mm) high
Cable
Standard size: 35 feet (10.7 m) or 100 feet (30.5
m) long x 0.28 inches (7.2 mm) nominal OD,
polyurethane jacket
Extension cables available up to 300 feet (91.4
m)
Operating /
Storage
Temperature
Operating: -4
°
to 140
°
F (-20
°
to 60
°
C)
Storage: -4
°
to 167
°
F (-20
°
to 75
°
C)
Note:
This sensor will
not
produce accurate
readings in frozen flow.
Upward Ultrasonic Depth
Upward Depth
Accuracy
0.5% of reading or +/- 0.125 inches (3.2 mm),
whichever is greater
Deadband
Extending 1.0 inch (25 mm) up from the
bottom
of
the sensor
Frequency
250 kHz – 1 MHz
Range
60 inches (1524 mm)
Resolution
0.01 inches (0.25 mm)
Drift
0