10-10 ADS Manual
4.
Close the Monitor Status window and then click on the
green
Hangup
button in the
Functions
section to discontinue
communication with the monitor.
Replacing the Monitor Battery Pack
Note:
The only service or maintenance activities ADS
permits within the monitor chassis are battery pack, battery
PCB, regulator/modem unit, and fuse replacement.
Therefore, do not handle, alter, modify, remove, or replace
any other components inside the monitor. Such actions
will void the monitor warranty agreement and the IS
certification.
Warning:
The
can receive internal power
only from the ADS 12-volt IS battery pack (p/n 8000-
0043-02/04). Do not use any other battery or power
source to power the monitor internally.
ADS offers a replacement 12-volt battery pack (ADS p/n 8000-
0043-02) to replace the existing battery pack when the battery
voltage is low or falls below the previously specified level.
Replacing the 12-volt battery pack involves a relatively simple
process.
Note:
Battery pack replacement involves removing the
existing PCB for reuse with the replacement battery pack.
Therefore, do not discard or replace the PCB unless it is
necessary.
Summary of Contents for Intrinsically-Safe TRITON+
Page 19: ...1 12 ADS TRITON Manual Control Drawing ...
Page 25: ...1 18 ADS TRITON Manual First page of the TRITON ATEX Certificate ...
Page 27: ...1 20 ADS TRITON Manual First page of the TRITON IECEx Certificate of Conformity ...
Page 29: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 1 ...
Page 30: ...Introduction 1 23 CSA Certificate of Compliance Page 2 ...
Page 32: ...Introduction 1 25 Sample TRITON Declaration of Conformity Page 2 ...