Configuration and Activation 6-31
Advanced Parameters
dialog
Note:
Modifications made to the Advanced Parameters
should be performed only by or under the guidance of
trained ADS personnel. Therefore, ADS recommends
leaving the default settings (
Auto
) in place.
Modify the parameters as necessary, and then select
OK
once
complete.
DAC Gain
Choose the method for managing the
amplification of the analog signal that returns to the sensor:
−
Auto
Select this option to allow the monitor to
automatically optimize the amplification of the signal.
−
Manual
Select this option to enter a fixed value
between -12db (lower amplification) and +12db (high
amplification) at which to amplify the signal.
Surcharge Detection
Select the
Disable
checkbox to
prevent the monitor from implementing the Surcharge
Detection function when processing smart depth data. For
locations that typically do not experience surcharges,
disabling Surcharge Detection eliminates the processing
time required for this function and, as a result, conserves
monitor power.