2-10 ADS Manual
Power
Internal Power
Power is supplied to the
flow monitor by an internal 12-
volt IS battery pack (ADS p/n 8000-0043-02/04). The battery pack
resides within the
enclosure and powers monitor
operations. A battery fuse board is attached to the battery pack to
achieve intrinsic safety.
12-volt battery
The power regulator, built into the dome assembly that covers and
protects the processor board, is critical to intrinsically safe
operation. It regulates the voltage supplied from the internal IS
battery pack to the
, ensuring that the monitor always
operates within its IS certification requirements. It also includes
replaceable fuses and current-limiting components that will limit
and/or interrupt power if a fault condition occurs.
Summary of Contents for Intrinsically-Safe TRITON+
Page 19: ...1 12 ADS TRITON Manual Control Drawing ...
Page 25: ...1 18 ADS TRITON Manual First page of the TRITON ATEX Certificate ...
Page 27: ...1 20 ADS TRITON Manual First page of the TRITON IECEx Certificate of Conformity ...
Page 29: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 1 ...
Page 30: ...Introduction 1 23 CSA Certificate of Compliance Page 2 ...
Page 32: ...Introduction 1 25 Sample TRITON Declaration of Conformity Page 2 ...