External Power
5-27
CABLE GLAND
GND WIRE
AC CABLE
Ground wire running from ExPAC through cable gland in enclosure
4.
Connect the free end of the 12-gauge ground wire to the earth
ground available at the location.
5.
Run the free end (
without the ring terminal
) of the
10-gauge
ground wire (from the
external power grounding kit
, ADS p/n
8000-0434-xxx) up through the cable gland on the right (
on the
XIO/XBUS
) or up through an available cable route from the
outside of the existing enclosure. The cable gland or entry
entry route referenced is the same gland/route through which
the
AC power cable
and other ground wire are exiting the unit.