Specifications
A-11
ParaDepth Sensor (ADS p/n 8K-CS8-D1-00-30-IS)
This sensor supports downward ultrasonic and air temperature
measurement only.
ParaDepth Sensor
Housing
Polycarbonate shell (PC)/ PEEK, epoxy-filled.
High visibility yellow color.
Dimensions
10.9 inches (277 mm) long x 2.28 inches (57.9
mm) wide x 2.58 inches (65.5 mm) high
Cable
Standard size: 30.0 feet (9.14 m) long x 0.30
inches (7.6 mm) nominal OD, polyurethane jacket
Extension cables available up to 300 feet (91 m)
Operating /
Storage
Temperature
Operating: -4° to 140° F (-20° to 60° C)
Storage: -4° to 167° F (-20° to 75° C)
Note: The sensor will not produce accurate
readings when ice is built up on the sensor.
Downward Ultrasonic Depth
Accuracy
0.125 inches (3.2 mm)
Deadband
0.0 inches (0 mm) from the face of the sensor
Frequency
125 kHz
Range
0.0 inches (0 mm) to 12.0 feet (3.66 m)
Resolution
0.01 inches (0.25 mm)
Drift
0 inches (0 mm)
ParaFlow Sensor (ADS p/n 8K-CS8-V2-10-30-IS)
This sensor supports downward ultrasonic, surface velocity,
surcharge velocity, surcharge pressure depth and air
temperature measurement.
Summary of Contents for 507165
Page 20: ...1 12 ADS TRITON Manual Control Drawing ...
Page 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Page 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Page 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Page 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Page 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Page 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Page 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Page 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Page 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Page 53: ...System Overview 2 13 ExPAC XBUS ...
Page 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Page 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Page 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Page 358: ...Inclinometer 8 3 ...
Page 507: ...C 4 ADS TRITON Manual ...
Page 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...