Configuration and Activation 4-35
Backward Bidirectional
Choose this option when the
AV|Gated Sensor is installed facing downstream and to
ensure the monitor analyzes flows moving both away from
and toward the face of the sensor. This option would be
beneficial, for example, when using a weir to measure
overflows with the potential of river intrusion.
z
Minimum Velocity
Select the minimum expected velocity
that may occur at the site for the monitor to use in fine-tuning
the velocity data. The default setting is 0.05 and should be used
in most instances. The monitor compares the
Minimum
Velocity
value to the actual velocity readings before storing to
the monitor memory. Any actual velocity reading falling within
a plus or minus range of zero using the
Minimum Velocity
value will be set to zero. For example, using a
Minimum
Velocity
of 0.05, and getting an actual velocity reading of -
0.03 causes the monitor to store a velocity reading of 0. Using
a
Minimum Velocity
of 0.05 and getting an actual velocity
reading of 0.06 causes the monitor to store a 0.06 velocity
reading.
z
Maximum Velocity
Select the maximum expected velocity
that will occur at the site for the monitor to use in fine-tuning
the velocity data. The default setting is
Auto
, which serves to
optimize the range and resolution of the velocity data samples
to match the characteristics of the flow.
z
Data Acquisition
Select the length of time to allow the
monitor to get a velocity reading. The default of
Auto
should
be used in most instances. Use
Low
to shorten the length of
time or use
Medium
or
High
to increase the amount of time.
Using
Medium
or
High
results in smoother velocity data but
also requires extra battery consumption.
z
Store Data
Select this checkbox to ensure the monitor logs
the velocity data to memory.
This option is selected by default.
z
Enable Scrubbing
Select this checkbox to ensure the
monitor confirms questionable or erroneous velocity readings
based on the historical relationship between the ultrasonic
depth and velocity data for the location.
Summary of Contents for 507165
Page 20: ...1 12 ADS TRITON Manual Control Drawing ...
Page 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Page 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Page 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Page 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Page 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Page 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Page 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Page 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Page 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Page 53: ...System Overview 2 13 ExPAC XBUS ...
Page 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Page 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Page 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Page 358: ...Inclinometer 8 3 ...
Page 507: ...C 4 ADS TRITON Manual ...