5-44 ADS
Manual
Mounting AV|Gated, AV|Max or Peak Combo
Sensors
Note:
Regardless of which band is used to install the
AV|Gated sensor,
it must be installed no more than +/- 5
degrees from the bottom center of the pipe.
If further
rotation is necessary, use a Silt Mount Adapter which will
allow the sensor to be rotated 30 degrees from center (7:00
position).
Two special installation methods are available for mounting these
sensors.:
z
¾-band mount
z
½-band mount
Both mounts require almost identical installation methods. The
only significant differences are that the ¾-band mount allows the
installer to secure the band to
both
sides of the pipe wall and to
position the sensor at the bottom center of the pipe. These options
are not possible using the ½-band mount. Therefore, the ¾-band
mount is the preferable method for mounting the sensors.
However, a ½-band mount may be appropriate for monitoring
under the following circumstances:
z
Large pipes with deep minimum flows
z
Large pipes with excessive silt present
½- (left) and ¾-band (right) mounts
Summary of Contents for 507165
Page 20: ...1 12 ADS TRITON Manual Control Drawing ...
Page 27: ...Introduction 1 19 CS6 LRD Sensor Certificate of Conformity ...
Page 29: ...Introduction 1 21 CSA Certificate of Compliance Page 1 of 7 ...
Page 30: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 2 of 7 ...
Page 31: ...Introduction 1 23 CSA Certificate of Compliance Page 3 of 7 ...
Page 32: ...1 24 ADS TRITON Manual CSA Certificate of Compliance Page 4 of 7 ...
Page 33: ...Introduction 1 25 CSA Certificate of Compliance Page 5 of 7 ...
Page 34: ...1 26 ADS TRITON Manual CSA Certificate of Compliance Page 6 of 7 ...
Page 35: ...Introduction 1 27 CSA Certificate of Compliance Page 7 of 7 ...
Page 37: ...Introduction 1 29 Sample TRITON Declaration of Conformity Page 2 ...
Page 53: ...System Overview 2 13 ExPAC XBUS ...
Page 266: ...5 60 ADS TRITON Manual z Installing the Submersion Sensor z Measuring the physical offset ...
Page 288: ...5 82 ADS TRITON Manual Topside Wall Mount Bracket Topside Sensor Bracket ...
Page 345: ...7 2 ADS TRITON Manual use of this installation guide or the installation of any ADS equipment ...
Page 358: ...Inclinometer 8 3 ...
Page 507: ...C 4 ADS TRITON Manual ...
Page 535: ...Index In 19 wiring to the monitor 6 29 XIO device parameters 4 84 ...